The short answer
A **cable-gland or metric conduit thread** in a CNC housing is not the same problem as [NPT versus a straight hydraulic port](https://3dwk.com/resources/npt-vs-straight-thread-port-notes-cnc-housings), and it is not an [O-ring groove](https://3dwk.com/resources/o-ring-groove-callouts-cnc-housings) by another name. A usable callout says the **thread designation** (metric gland thread such as M16 or M20, or a PG size, only if that is what you use), the **standard or class you cite**, the **thread length and entry**, the **sealing face** the gland nut or washer will sit on, and **keep-outs** for wall thickness and the gland body. Silence, or a note that only says “add a cable gland hole,” is what widens many [quote-new.php](https://3dwk.com/quote-new.php) **rates.v1.1** estimate bands—not the tapping minutes alone.
This guide is for buyers packaging CNC housings that must accept a metric or PG cable gland or conduit entry. Illustrations use an **Example part** only—not a customer enclosure, and not a fabricated IP-rating certificate. Sibling notes cover NPT versus straight ports; here we focus on **buyer packaging of gland threads, sealing faces, and keep-outs**.
What cable-gland threads mean for quoting
A **gland-thread pack** names the designation, the standard if you cite one, whether the hole is through or a specified entry depth, the sealing face, and clearance for the gland. Writing “cable entry” or “standard gland thread” is not enough. Process pages for common CNC housings ([CNC 3-axis Al 6061 automation](https://3dwk.com/en/cnc-3axis/al-6061/automation.html), [CNC 3-axis Al 6061 electronics-thermal](https://3dwk.com/en/cnc-3axis/al-6061/electronics-thermal.html), [CNC 3-axis Al 6061](https://3dwk.com/en/cnc-3axis/al-6061.html)) assume the pack is visible when lots mix clearance holes, NPT ports, and metric gland threads.
Do not bury “gland as needed” inside a notes cloud. Put **CABLE GLAND THREAD: DESIGNATION AND STANDARD CITED, THREAD LENGTH CITED, SEALING FACE FLAT AND UNINTERRUPTED, KEEP-OUT FOR GLAND BODY AND WALL** on the PDF and mirror it in RFQ text. If the wall should stay a clearance hole or a knockout with no thread, say **NO GLAND THREAD; CLEARANCE HOLE CITED** so the shop does not tap a metric entry by habit. Background: [what files to send for a CNC quote](https://3dwk.com/resources/what-files-to-send-for-cnc-quote), [designing threads and tapped holes](https://3dwk.com/resources/designing-threads-and-tapped-holes).
Designation, class, and sealing face
Write the exact designation the gland requires—metric threads with pitch, or a PG size—and the standard or thread class if the program names one. This guide does not invent a default class, a default pitch, or a 3DWK-standard “M20 gland.” A through-tapped wall is a different RFQ from a thread that stops at a shoulder or a reduced bore. Call the length, the entry chamfer if you care, and whether the inside must stay free of burrs or tap breakout.
The sealing face is part of the pack. Many glands need a flat, undamaged face for a washer, O-ring, or gland shoulder. If paint, powder, or anodize will cover that face, say whether it is masked; finish-mask discipline is the same as on other housing faces. An IP or dust rating is a **system result** of the gland, the cable, and the face—not something a thread note by itself can guarantee.
Keep-outs, wall thickness, and internal clash
Give a minimum wall around the thread and a keep-out for the gland body, locknut, and wrench access so the entry does not sit on a thin corner or collide with an internal board, a boss, or a [bearing seat](https://3dwk.com/resources/bearing-seat-notes-cnc-housings). If two entries share a wall, say the spacing. A thread that breaks into an O-ring groove, a connector bore, or a cooling channel is a different RFQ from a dedicated pad. Related housing notes: [vent, drain, and weep holes](https://3dwk.com/resources/vent-drain-weep-holes-cnc-housings).
Tolerance and inspection traps
Calling “standard cable gland,” leaving the designation off a hole shown only as a circle, or asking for an IP rating with no gland part and no face requirement, all force **needs_manual**. Default a housing that only needs a clearance hole to an explicit no-thread note; do not let a metric gland appear as an implied tap. Related: [what needs_manual means](https://3dwk.com/resources/what-needs-manual-means-preliminary-quote).
Illustration 1 shows an **Example part** Al 6061 housing with a labeled metric gland thread, designation and standard cited by the buyer, thread length cited, a flat sealing face, and keep-outs for wall thickness and the gland body.
Example part walkthrough
**Example part:** Al 6061 housing, one metric cable-gland thread required, designation and standard cited on the PDF, thread length cited, sealing face flat and unpainted if the gland requires it, keep-outs for wall and gland body, no invented default thread class, pitch, or 3DWK gland recipe. With STEP + **GLAND THREAD DESIGNATION / STANDARD CITED; LENGTH CITED; SEALING FACE FLAT; KEEP-OUT FOR BODY AND WALL**, expect a usable automatic planning band on [quote-new.php](https://3dwk.com/quote-new.php). Same geometry with silent “add a cable gland as needed” often lands DFM notes or **needs_manual**—without inventing any customer enclosure, IP certificate, or a 3DWK-guaranteed seal.
Illustration 2 contrasts a vague RFQ (“cable gland hole”) versus a labeled designation-face-keep-out pack and the clearer estimate path.
What widens bands fastest
Unlabeled “as needed” gland holes, a thread with no designation, a sealing face left painted or interrupted, and keep-outs omitted on thin walls. Quantity breaks do not erase feature-pack ambiguity—see [how quantity breaks change CNC unit cost](https://3dwk.com/resources/how-quantity-breaks-change-cnc-unit-cost).
What to do next
Mark each entry with **designation and standard, length, sealing face, and keep-outs**, then upload the CAD on [quote-new.php](https://3dwk.com/quote-new.php). Packaging checklist: this is not an NPT port and not an O-ring groove; keep hydraulic or face-seal notes on their own lines. Service pages: [CNC machining](https://3dwk.com/cnc-machining-service.php), [materials](https://3dwk.com/materials.php). Treat **rates.v1.1** min/mid/max as estimates, not invoices. If the UI shows **needs_manual**, answer the gland-thread questions rather than forcing a fake price.
Common questions
Is a metric gland thread the same as an NPT or straight hydraulic port?
No. NPT is a tapered pipe thread; many hydraulic ports are straight threads with a face or port seal. A cable-gland entry follows the gland’s metric or PG designation and usually needs a flat sealing face for the gland, not a port-boss standard. Package the designation you actually use.
Do I have to name a thread class if I give an M20 hole?
Name the designation and pitch, and cite the class or standard if the program uses one. This guide does not invent a default class or a 3DWK “standard M20 gland.”
Can the thread break out into a thin wall or an internal pocket?
Only if you say so. A default keep-out for wall thickness, gland body, and internal clash is safer. If the wall is too thin for the thread you want, change the pad or the gland size on the PDF.
How should I inspect the entry?
Call out the designation (and class if cited), usable thread length, and the sealing-face condition. An IP rating still belongs to the assembled gland and cable; do not treat a tapped hole alone as a sealed enclosure.