The short answer
Specify a 2B internal thread, and a 2A external thread, when you need a normal commercial fit that assembles by hand and holds a fastener. That pair is the usual starting point on a CNC drawing. Call 3B, and 3A on the mating screw or stud, only when you have a reason for a tighter pitch-diameter fit — a fine adjustment, a thread that must not feel sloppy, or a class copied from a standard you actually named — and you are willing to inspect it that way. For metric threads, the everyday equivalent is typically a 6H internal thread and a 6g external thread; a tighter number-and-letter fit is the analogue of moving from 2B toward 3B. Write the class on the thread callout, and upload the PDF with the STEP through quote-new.php so the shop quotes that class, not a general request for “tight threads.”
Class is a fit, not a position tolerance
Unified classes such as 2A, 2B, 3A, and 3B, under the usual ASME B1.1 system, and ISO 965 fits such as 6H and 6g, set how far the pitch diameter, major diameter, and minor diameter may sit from the basic thread profile. They do not replace a position tolerance, a perpendicularity callout on the axis, or a usable-thread depth. A 3B hole can still be out of position; a 2B hole with a clear position frame can locate a pattern more honestly than a tight class with no datum scheme (see GD&T basics for buyers, and designing threads and tapped holes for machined parts).
Internal threads use the B letter in the Unified system, or a capital letter such as H in the metric system. External threads use A, or a lowercase letter such as g or h. Treat the two sides as a pair: a 3B hole mated to a commodity 2A screw is not the same joint as a 3A/3B pair, and a plated 2A screw may not enter a 3B hole the way a bare 2A screw would. Class 1A and 1B exist for a looser fit and are uncommon on precision CNC parts.
A blanket “3B” note is not a quality upgrade. It is a tighter pitch-diameter window. If what you actually need is engagement length, usable depth, or hole position, write those (see thread engagement length notes for CNC, thread depth callouts on blind tapped holes, and dowel-pin hole location DFM for CNC).
When 2B and 2A are the right default
Ordinary fasteners, covers, and service joints
Use 2B on internal threads, and 2A on external threads, for the bulk of CNC work: cover screws, clamp bolts, service fittings, and any joint whose mating part is a standard commercial fastener. The 2A/2B pair is the general-purpose Unified fit, and it is the class most catalog screws are made to. A tighter class on those holes rarely improves the joint, and it can make a catalog 2A or 6g fastener harder to start.
Metric drawings: start from 6H and 6g
On a metric ISO thread, a 6H internal thread and a 6g external thread play the same general-purpose role as 2B and 2A. If the print only says “M8 × 1.25” with no fit, a shop will typically assume that medium fit, but you should still write 6H or 6g so the assumption is explicit. Do not place a Unified class letter on a metric designation, or an ISO fit on a UNC, UNF, or UNEF callout.
When a 3B or 3A class is justified
A tighter pitch-diameter fit, on purpose
Specify 3B on an internal thread, or 3A on an external thread, when you want less clearance in the thread itself: an adjusting screw that should not feel sloppy, a stud that must stay put, or a threaded interface designed around that tighter class. The class still does not locate a hole pattern. If location is the real requirement, add the position or profile frame and keep the thread class only as tight as the fit requires (see position vs profile tolerances on CNC brackets).
When a named specification already requires it
Some product standards or interface documents call 3A/3B, or a tighter metric class such as 4H or 5H, on particular joints. If you are following one of those documents, name it on the drawing and use the class it requires. Do not upgrade every other thread on the same part to match a single specified joint.
Hard parts and threads finished after heat treat
A 3A or 3B callout on a hardened steel thread often implies a different routing than a 2B hole tapped while the part is still soft. Thread grinding after heat treat is a common way to hold a tight class on a hard external thread. A tight internal thread in hard steel may need a hard-material tap, a thread mill, or grinding, and it may belong after heat treat rather than before (see should I cut threads before or after heat treat). If the class is 3A or 3B and the part is quenched and tempered, write that sequence. Do not assume a soft-state tap will still gauge 3B after the furnace.
Coatings, inserts, and which size you will accept
Plating and anodize add thickness on the thread flanks. A 2A external thread that is in class before zinc plating or electroless nickel can sit outside that class after the coating, and may not enter the mating 2B or 3B hole (see zinc plating vs electroless nickel vs black oxide for steel parts, and plating thickness and the CNC tolerance stack). Typical practice is to state whether the class applies before or after the coating, and to leave a coating allowance on external threads so the finished thread still gauges the class you need. If an internal thread will be coated, say whether it is gauged before coating, after coating, or both. Type II or Type III anodize on an aluminum tapped hole raises the same question (see anodizing Type II vs Type III, and as-machined before Type II anodize).
Thread inserts move the class question rather than removing it. The finished thread in the insert is usually a stated class, often 2B or 6H unless you have specified otherwise (see thread inserts vs tapped holes in aluminum, and Helicoil vs tapped holes for CNC aluminum). Write the insert type and the class of the assembled thread. If the class is tight, gauge after any hydrogen bake or other thermal step as well (see when to specify a hydrogen bake after plated CNC steel, and when to specify passivation after CNC stainless).
Inspection has to match the class you wrote
A 2B or 6H hole is commonly accepted with a go/no-go thread plug gauge of that class. A 3B hole should be gauged to 3B, not checked with a 2B go gauge and a look at the start of the thread. If you also want a reported pitch diameter, say so; that is a different inspection load than functional gauges alone (see go/no-go thread inspection notes for CNC lots, and first article inspection). External 3A threads are often checked with 3A ring gauges, and with a pitch-diameter measurement when the print asks for it.
Name the standard you actually use — typically ASME B1.1 for Unified classes and ISO 965 for metric fits — and the gauge practice, such as ASME B1.2 or the ISO gauge document on your drawing. On a part with many similar holes, say whether every hole is gauged, or a first-article layout plus a sampling plan (see CMM sampling plans for CNC lots). Thread milling versus tapping can change how the shop holds class, but lock the process on the RFQ only when you have a reason (see thread milling vs tapping for CNC buyers).
What to put on the drawing and the RFQ
The thread note should be readable on the PDF that accompanies the STEP:
- The thread designation, including series and pitch (for example, 1/4-20 UNC or M8 × 1.25), and the class or fit (2B, 3B, 6H, and so on)
- Whether the feature is internal or external, and whether it is a through hole, a blind hole with a usable depth, or an external length (see blind vs through holes on CNC RFQ notes, and thread relief and runout notes on turned CNC parts)
- Whether class applies before or after plating, anodize, or paint, and any coating allowance on external threads
- The heat-treat sequence if the part is hardened: cut or mill the thread soft, or finish the thread after heat treat
- Insert type and the class of the finished, assembled thread, when an insert is required
- The thread standard and the gauge practice, plus go/no-go and any pitch-diameter reporting
- Which holes are 3B, or a tight metric class, if only some of them are — do not hide a mixed-class part behind one general note
ISO 2768 general tolerances do not set thread class, and a title-block note such as ISO 2768-mK does not turn an unclassified M8 into 6H or upgrade 2B to 3B (see ISO 2768 general tolerances).
Mistakes that show up at the gauge
The most common error is a blanket 3B or 4H note on every hole, including cover screws assembled with commodity 2A or 6g fasteners. The second is writing 3B and then inspecting with a 2B gauge. The third is omitting whether class applies before or after plating, so shops quote different allowances. The fourth is putting a Unified class on a metric thread, or leaving the class off, and discovering the mismatch at first article. The fifth is expecting a 3B hole to correct a loose position tolerance. The sixth is tapping 3B soft, then hardening, without a plan to finish or gauge after heat treat. The seventh is specifying a 3B finished thread in an insert hole without naming the insert. A class letter is not a general “make it precise” stamp.
A last look at the files
On quote-new.php, check that the drawing shows:
- 2B/2A or 6H/6g as the default, with 3B/3A or a tighter metric class only on the joints that need it
- Class applied before or after coating, with an allowance where it is required
- Heat-treat sequence for any hard thread
- Gauge practice that matches the class
- A PDF that agrees with the STEP
What drives CNC machining cost and what affects CNC machining lead time both move when you add a tight thread class, a hard-material thread, a coating allowance, or 100 percent 3B gauging, so name those requirements on the first RFQ. If the files already show the class, upload them through quote-new.php and ask for a quote to that callout, not to “tight threads as required.”